APERA PC850 Taşınabilir pH/İletkenlik/TDS Metre Takımı
The PC850 from Apera Instruments is a handy and easy-to-use meter for the determination of pH, conductivity (EC), TDS, ORP (electrode sold separately e.g. 301Pt-C) and temperature. It is protected by a silicone cover and is waterproof and dustproof (IP57), making it particularly well suited for field use, even in harsh environments. The 201T-F pH electrode features a unique low-resistance glass membrane for fast and accurate pH measurements. The 2031T-S conductivity electrode is based on our BPB (Brush-resistant Platinum Black) electrode technology and is characterized by its precision and very wide measuring range (0 – 200 mS/cm). Both electrodes are equipped with an integrated temperature sensor, which enables automatic temperature compensation (ATC) in each case.
- Equipped with the 201T-F pH electrode and the 2031T-S conductivity electrode, each with integrated temperature sensor
- Silicone case provides safe & firm grip and protects from shocks
- Waterproof and dustproof (IP57) for use in harsh environments
- Fold-out stand for convenient indoor operation
- Quick and easy 1- to 3-point calibration
- Large, illuminated LCD simultaneously displays conductivity value, pH value and temperature, as well as additional measurement and calibration information
- Self-diagnosis supports calibration or troubleshooting
- BNC connector is compatible with LabSen® series electrodes for even more application possibilities
pH | Measuring range | 0.00 to 14.00 pH |
Resolution | 0,1/0,01 | |
Accuracy | ±0,01 ±1 digit | |
calibration | 1 to 3 points, automatic | |
Temperature compensation | 0 to 100 ° C (automatic or manual) | |
mV | Measuring range | ±1000 mV |
Resolution | 1 mV | |
Accuracy | ±0.2 % F.S. ± 1 digit | |
Conductivity (EC) | Measuring range | 0 to 200 mS/cm: (0.00 ~ 19.99) μS/cm; (20.0 ~ 199.9) μS/cm; (200 ~ 1,999) μS/cm; (2.00 ~ 19.99) mS/cm; (20.0 ~ 199.9) mS/cm TDS: 0 to 100 g/l |
Resolution | 0.01/0.1/1 μS/cm; 0.01/0.1 mS/cm | |
Accuracy | ±1.0 % F.S ±1 digit | |
Temperature compensation | 0 to 50 °C (automatic or manual) | |
Cell constant | 0,1/1/10 cm-1 | |
calibration | 1 to 3 points, automatic | |
Temperature | Measuring range | 0 to 100 °C |
Resolution | 0,1 °C | |
Accuracy | ±0,5 °C ±1 digit | |
more | Power supply | 3 x AA batteries |
Housing protection class | IP57 | |
Electrode connection | BNC (for pH/ ORP), 8-pin (for conductivity), RCA (for temperature) |
|
Dimensions / Weight | 88×170×33 mm / 313 g
with case: 360×270×76 mm / 1.4 kg |
A complete set contains:
- PC850 pH/conductivity meter
- 201T-F pH electrode
- 2301T-S Conductivity electrode
- pH calibration solution (pH 4.00 / pH 7.00 / pH 10.01; 50ml each)
- EC calibration solution (84 μS/cm; 1413 μS/cm; 12.88 mS/cm, 50ml each).
- Screwdriver
- operation manual
- Carrying case