- Base unit with no Cab Filters
- Auto Polarity in DC functions
- Both Auto and Selectable DC Amps Polarity
- Direct measurement of Code Parameters
- Ohmmeter Voltage Mode detects foreign AC or DC Voltages
- Relay Contact On Time (Dry Contact) requires no adjustment
- Peak measurements require no adjustment
- Lead time for NIST Certified products is 5-7 business days
- Upon order placement, please provide the company name that should appear on the certificate. Without this information, we will not be able to provide a certificate of calibration.
Demiryolları Analog Test Aygıtı 2000 serisi
Demiryolları Analog Test Aygıtı 2000 serisi
The 2000 Series Railroad Testers are designed to perform standard
maintenance tasks (using Volts, Ohms, and Amps measurements) as well as
specialized tasks requiring measurements on railroad coding equipment.
The 2000 Series is compatible with older test technologies and offers
test features not found on earlier test sets.
2010/2011/2012/2013-NIST Comes with Certificate of traceability to NIST standards
2010/2011/2012/2013-NIST Comes with Certificate of traceability to NIST standards
Specifications | Model 2000 | Model 2001 | Model 2002 | Model 2003 |
DC Voltage | 0.6V, 3V, 15V, 60V, 300V | 0.6V, 3V, 15V, 60V, 300V | 0.6V, 3V, 15V, 60V, 300V | 0.6V, 3V, 15V, 60V, 300V |
DCV Accuracy | ±1.5% FS | ±1.5% FS | ±1.5% FS | ±1.5% FS |
DC Milliamps | 16mA, 60mA, 300mA | 16mA, 60mA, 300mA | 16mA, 60mA, 300mA | 16mA, 60mA, 300mA |
DC mA Accuracy | ±1.5% FS | ±1.5% FS | ±1.5% FS | ±1.5% FS |
DC Amps | 1.5A, 6A, 30A | 1.5A, 6A, 30A | 1.5A, 6A, 30A | 1.5A, 6A, 30A |
DCA Accuracy | ±1.5% FS | ±1.5% FS | ±1.5% FS | ±1.5% FS |
AC Voltage | 1.5V, 3V, 15V, 150V, 300V, 600V | 1.5V, 3V, 15V, 150V, 300V, 600V | 1.5V, 3V, 15V, 150V, 300V, 600V | 1.5V, 3V, 15V, 150V, 300V, 600V |
ACV Accuracy | ±3.0% FS | ±3.0% FS | ±3.0% FS | ±3.0% FS |
AC Amps | 1.5A, 6A, 30A | 1.5A, 6A, 30A | 1.5A, 6A, 30A | 1.5A, 6A, 30A |
ACA Accuracy | ±3.0% FS | ±3.0% FS | ±3.0% FS | ±3.0% FS |
Cab Filter Response (All AC ranges) |
60Hz: — 100Hz: — 200Hz: — 250Hz: — |
60Hz: — 100Hz: 92 to 100Hz 200Hz: — 250Hz: 245 to 255Hz |
60Hz: — 100Hz: 92 to 100Hz 200Hz: 196 to 204Hz 250Hz: — |
60Hz: 57 to 63Hz 100Hz: 92 to 100Hz 200Hz: — 250Hz: — |
Code Functions (All AC and DC Ranges) |
On Time: 3% to 100% (±3% FS) Rate: 30 to 500CPM (±3% FS) Peak Hold: Ö Peak Follow: Ö |
On Time: 3% to 100% (±3% FS) Rate: 30 to 500CPM (±3% FS) Peak Hold: Ö Peak Follow: Ö |
On Time: 3% to 100% (±3% FS) Rate: 30 to 500CPM (±3% FS) Peak Hold: Ö Peak Follow: Ö |
On Time: 3% to 100% (±3% FS) Rate: 30 to 500CPM (±3% FS) Peak Hold: Ö Peak Follow: Ö |
Volt Senese Mode | 15V AC or DC (±20%) | 15V AC or DC (±20%) | 15V AC or DC (±20%) | 15V AC or DC (±20%) |
Resistance | Range: R x 1 and R x 100 Center Scale: 5 and 500 ohms Accuracy: ±2% of scale length |
Range: R x 1 and R x 100 Center Scale: 5 and 500 ohms Accuracy: ±2% of scale length |
Range: R x 1 and R x 100 Center Scale: 5 and 500 ohms Accuracy: ±2% of scale length |
Range: R x 1 and R x 100 Center Scale: 5 and 500 ohms Accuracy: ±2% of scale length |
Dry Contact | Allowable Resistance: 0 to 100 ohms Test Voltage: 7.5 to 15VDC Test Current: less than 1mA |
Allowable Resistance: 0 to 100 ohms Test Voltage: 7.5 to 15VDC Test Current: less than 1mA |
Allowable Resistance: 0 to 100 ohms Test Voltage: 7.5 to 15VDC Test Current: less than 1mA |
Allowable Resistance: 0 to 100 ohms Test Voltage: 7.5 to 15VDC Test Current: less than 1mA |
Power | (2) 9V; (1) 1.5V D cell | |||
Dimensions | 5 x 6.5 x 3.2" (127 x 165.1 x 81.3mm) | 5 x 6.5 x 3.2" (127 x 165.1 x 81.3mm) | 5 x 6.5 x 3.2" (127 x 165.1 x 81.3mm) | 5 x 6.5 x 3.2" (127 x 165.1 x 81.3mm) |
Weight | 4.75 lbs (2.15kg) with case and leads | 4.75 lbs (2.15kg) with case and leads | 4.75 lbs (2.15kg) with case and leads | 4.75 lbs (2.15kg) with case and leads |